COMEN STAR 8000 Patient Monitor Multi Parameter
COMEN STAR 8000 Patient Monitor Multi Parameter
COMEN STAR 8000 Patient Monitor Multi Parameter
COMEN STAR 8000 Patient Monitor is refined and has high-end quality. It is designed strictly following CE standards. It's robust and stable with a solid anti-interference capability. Comen checks every process throughout R&D and production per international standards. They also conduct clinical tests in hospitals to ensure that each product is of the highest quality. Parameters: ECG/HR, SpO2, PR NIBP, and TEMP. Comen's CardioTec TM ECG Monitoring Technology offers 13 different types of arrhythmia analysis and ST segment analysis and better precision of ECG measurement. Comen's DioxTM Digital SpO2 Technology allows precise measurement even under poor perfusion and trembling finger conditions; AcuTec TM Blood Measuring Technology and the analysis of the hemodynamic characteristics of patients at high risk to ensure accurate BP measurement.
Features:
- 1-inch high HD resolution TFT color screen
- The only NIBP-specific button, as well as the NIBP dust shield
- Helpline Nurse Connection
- Fully meeting the essential monitoring needs
- Independent NIBP Button
- Support for USB and SD card connections
- Convenient Handle
- Excellent NIBP dust Shield Design
- Various mount solution
Standard Configuration:
- ECG/HR
- SpO2
- NIBP
- Respiration
- Temperature
- Pulse
Optional Configuration:
- Nellcor SpO2
- Thermal Recorder
- Wire/Wireless Central Monitor Station
- Unique Accessories for Neonatal and Pediatric Patients
Specifications:
ISO 13485 | 2003 approved, CE marking according to MDD93/42/EEC |
Dimension | 320mm×170mm×280mm |
Weight | 6kg |
Power | AC100-250V, 50/60Hz. |
Temperature | 0-40˚C |
Humidity | 15-85% |
Patient Range | Adult, Pediatric, and Neonate patients |
Display |
12.1inch colour TFT (diagonal) Resolution: 800x600 |
Trace | 5 waveforms Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s |
Indicator | Power indicator light Battery indicator light Alarm indicator light |
Inter face | Parameter cable inter face AC Power input socket Network inter face |
Battery | lead-Acid /Rechargeable 5 hours for continuous working |
Trend time | 1~96 hours |
Alarm | User-adjustable High and Low limits alarm events recallable audible and visual alarm |
Networking | Connected to central monitoring system |
Recorder | Built-in, thermal array, 2 traces, paper width:50mm Record mode: manual, on alarm, time-defined |
Print speed | 12.5 mm/s, 25mm/s, 50mm/s |
Lead selection | 5-Lead and 3-lead selectable |
5 leads | RA; LA; RL; LL; V or R; L; N; F; C, |
3 leads | RA; LA; LL or R; L; F |
ECG waveform | 2 channels |
Gain selection | ×1/4, ×1/2, ×1, ×2, Auto |
Sweep speed | 12.5mm/s, 25mm/s, 50mm/s |
Heart Rate Range | 15 ~ 350bpm |
Accuracy | ±1% or ±2bpm whichever is greater |
Resolution | 1 bpm |
Waveform | Standard 5 ECG waveforms |
Pace detection | Yes |
HR alarming time | ≤12s |
Input impedance | > 5 M |
Method | Thoracic impedance |
RR measurement range | 0-100rpm |
Resolution | ±1 rpm |
Accuracy | ±1rpm |
Measurement range | 0-100% |
Resolution | ±1% |
Accuracy | ±1% (90-100%) 2% (70-89%) |
Pulse Rate range | 0~250 bpm |
Pulse Rate Accuracy | ±1bpm |
Measurement method | Automatic oscillometric |
Measurement types | Systolic, Diastolic, Mean |
Work mode | Manual / Automatic |
Auto measurement time | Adjustable |
Measurement unit | mmHg / KPa selectable |
Range of systolic pressure |
Adult mode: 40~270 mmHg Pediatric mode: 40~200 mmHg Neonate mode: 25~135 mmHg |
Range of diastolic pressure |
Adult mode: 30~200 mmHg Pediatric mode:20~150 mmHg Neonate mode: 10~110 mmHg |
Range of mean pressure |
Adult mode: 30~220 mmHg Pediatric mode 30~160 mmHg Neonate mode: 20~170 mmHg |
Accuracy | ±5 mmHg |
NIBP pressure range | 0~300 mmHg |
PR from NIBP | Measurement 40-240 bpm |
Over-pressure protection | Double safety protection |
Measurement range | 20-45˚C |
Resolution | 0.1˚C |
Accuracy | 0.1˚C |
Measurement unit | ˚C/F selectable |
Sample Gas Flowrate | 50ml/mi |